Skip to content
GitLab
Explore
Sign in
Primary navigation
Search or go to…
Project
P
PrintingMachineProgram
Manage
Activity
Members
Labels
Plan
Issues
Issue boards
Milestones
Wiki
Code
Merge requests
Repository
Branches
Commits
Tags
Repository graph
Compare revisions
Snippets
Build
Pipelines
Jobs
Pipeline schedules
Artifacts
Deploy
Releases
Package registry
Container registry
Model registry
Operate
Environments
Terraform modules
Monitor
Incidents
Service Desk
Analyze
Value stream analytics
Contributor analytics
CI/CD analytics
Repository analytics
Model experiments
Help
Help
Support
GitLab documentation
Compare GitLab plans
Community forum
Contribute to GitLab
Provide feedback
Terms and privacy
Keyboard shortcuts
?
Snippets
Groups
Projects
Show more breadcrumbs
Post, Fabian
PrintingMachineProgram
Repository graph
Repository graph
You can move around the graph by using the arrow keys.
main
Select Git revision
Branches
4
develop
feature/VA-100_Modbus_RTU
main
default
protected
stepperControl
4 results
Begin with the selected commit
Created with Raphaël 2.2.0
2
Apr
7
Mar
6
24
Feb
16
Oct
14
18
Sep
16
13
20
Aug
15
8
24
Jul
19
Jun
18
15
May
6
3
25
Apr
9
Feb
8
31
Jan
5
3
- fixed a bug where viscosity of VA-100 was converted incorrect
feature/VA-100_…
feature/VA-100_Modbus_RTU
- state of experiments at 07.03.2025
- now only throws error for PB if value is False for more than 3 seconds (not tested)
MAIN UI:
- modificiations in sequence procedure and sequential parameter loading
- status before updating x-axis parameters
- updated cliche axis parameters to accurately move the desired milimeters
- adapted cliche motor configuration to new spindle
- encapsulated code in new vi (save_data_to_CSV)
- backup latest changes before pc update
SMCI: adapted stepper control is now working properly
- SMCI33-1 control: created Sub-Vis for different operations
-successfully tested communication with viscosimeter and stepper motor
Merge branch 'feature/stepperSMCI33-1' into develop
develop
develop
- no real changes
- added vi that computes viscosimeter measurement
- tested force sensor filter, does not work proplerly
?
Merge remote-tracking branch 'origin/feature/stepperSMCI33-1' into feature/stepperSMCI33-1
- main.vi: in data collection -> testing FIR filter: replaced insert into array with replace subset (bugfix)
- main.vi: in data collection -> testing FIR filter: replaced insert into array with replace subset (bugfix)
-fixed phx 14 state bug
- added filter to force sensor. not tested yet
- further fixes on updating current state information
- fixed a bug in which current state data is not properly updated, because the update waited for the actors to finished their movement
- load cell now measures Newton (as was done in TC tests)
- minor changes in error wiring
- updated load cell parameters
Revert "- updated load cell parameters"
- updated load cell parameters
- fixed bugs -> working version
- various stuff
- example vi works with current setup
- fixed temp sensor missing in project
Merge branch 'feature/stepperControl' into develop
- stepper works with simple step rectangle signal
- added working VI that controls stepper motor via scanengine
stepperControl
stepperControl
no message
main
main
- removed unused file
- in_development now uses timer(subvi)_self.vi